Multi-tech-systems Modem Module MT3334SMI Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Hardware Multi-tech-systems Modem Module MT3334SMI. Multi-Tech Systems Modem Module MT3334SMI User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
ModemModule
Model MT3334SMI Evaluation Kit
Data/Fax Socketed Modem
Developers Guide
Vista de página 0
1 2 3 4 5 6 ... 73 74

Resumo do Conteúdo

Página 1 - Developer’s Guide

ModemModuleModel MT3334SMI Evaluation KitData/Fax Socketed ModemDeveloper’s Guide

Página 2 - Trademarks

ModemModule Developer’s GuideMT3334SMI10Test/Demo Board SpecificationsThe ModemModule Test/Demo Board kit includes a modem module, a power transformer

Página 3 - Contents

Chapter 1 - Introduction and DescriptionMT3334SMI 11Test/Demo Board Block DiagramSpeaker DS1SocketModemPowerSupplyPowerSwitchPowerConnectorRJ-11Conne

Página 4 - Appendixes

ModemModule Developer’s GuideMT3334SMI12MT3334SMI Pin-outThe MT3334SMI uses a 20-pin interface to provide an on-board DAA with tip and ring connection

Página 5

Chapter 1 - Introduction and DescriptionMT3334SMI 13Typical ApplicationThe table below shows the MT3334SMI pinouts and Figure 1-6 illustrates a typica

Página 6 - Features

ModemModule Developer’s GuideMT3334SMI14MT3334SMI Design ConsiderationsThis section discusses hardware considerations, PC board layout considerations,

Página 7 - Technical Specifications

Chapter 1 - Introduction and DescriptionMT3334SMI 15Safety: All creepages and clearances for the MT3334SMI have been designed to meet requirementsof

Página 8 - MT3334SMI8

ModemModule Developer’s GuideMT3334SMI16MT3334SMI PlacementFigure 1-8 illustrates where to place the MT3334SMI on a typical Motherboard. It must be pl

Página 9 - Physical Dimensions

Chapter 1 - Introduction and DescriptionMT3334SMI 17Telecom Labeling RequirementsFCC regulations require labeling of registered Telephone and Data Ter

Página 10

ModemModule Developer’s GuideMT3334SMI18Reregistration(From Form 730 Application Guide Appendix C-2) http://www.fcc.gov/formpage.htmlPrivate label d

Página 11 - Test/Demo Board Block Diagram

Chapter 2 - AT Commands, S-Registers,and Result Codes

Página 12 - MT3334SMI Pin-out

Developer’s Guide88312201 Revision BModemModule (Model MT3334SMI)This publication may not be reproduced, in whole or in part, without prior expressed

Página 13 - Typical Application

ModemModule Developer’s GuideMT3334SMI20IntroductionThe AT commands are used to control the operation of your modem. They are called AT commandsbecaus

Página 14 - Loaded 4 Pin Modjack

Chapter 2 - AT Commands, S-Registers, and Result CodesMT3334SMI 21Command: Bn Communication Standard SettingValues: n = 0–3, 15, 16Default: 1 and 16De

Página 15

ModemModule Developer’s GuideMT3334SMI22Command: In Information RequestValues: n = 0–5, 9, 11Default: NoneDescription: I0 Display default speed and co

Página 16

Chapter 2 - AT Commands, S-Registers, and Result CodesMT3334SMI 23Command: Sr? Read Register ValueValues: r = S-register numberDefault: NoneDescriptio

Página 17 - FCC Part 68

ModemModule Developer’s GuideMT3334SMI24Command: &Fn Load Factory SettingsValues: n = 0Default: NoneDescription: &F0 Load factory settings as

Página 18 - Reregistration

Chapter 2 - AT Commands, S-Registers, and Result CodesMT3334SMI 25Command: &Zy=x Store Dialing CommandValues: y = 0–3 (callback security disable

Página 19

ModemModule Developer’s GuideMT3334SMI26Command: \Nn Error Correction Mode SelectionValues: n = 0–5, or 7Default: 3Description: \N0 Non-error correcti

Página 20 - Introduction

Chapter 2 - AT Commands, S-Registers, and Result CodesMT3334SMI 27Command: %DCn AT Command ControlValues: n = 0 or 1Default: 0Description: %DC0 T

Página 21 - MT3334SMI 21

ModemModule Developer’s GuideMT3334SMI28S-RegistersCertain modem values, or parameters, are stored in memory locations called S-registers. Use the Sco

Página 22 - MT3334SMI22

Chapter 2 - AT Commands, S-Registers, and Result CodesMT3334SMI 29S43 decimal 0–1 1 For testing and debugging only. Enables/disables V.32bis start-up

Página 23 - MT3334SMI 23

iiiContentsChapter 1 - Introduction and DescriptionIntroduction ...

Página 24 - MT3334SMI24

ModemModule Developer’s GuideMT3334SMI30Result CodesIn command mode your modem can send responses called result codes to your computer. Resultcodes ar

Página 25 - MT3334SMI 25

Chapter 3 - Class 1 Fax Commands

Página 26 - MT3334SMI26

ModemModule Developer’s GuideMT3334SMI32IntroductionThe Service Class 1 standard (EIA/TIA-578) defines the commands that a PC user may issue toconfigu

Página 27 - MT3334SMI 27

Chapter 3 - Class 1 Fax CommandsMT3334SMI 33Table 3-1. Fax MOD (Modulation) Parameter ValuesValue Modulation Speed (bps) Requirements3 V.21 ch.2 300

Página 28 - S-Registers

ModemModule Developer’s GuideMT3334SMI34Command: +FCLASS=<value> <Enter>Function: Select Service ClassValues: 0, 1, 2Default: 0 (data mod

Página 29 - MT3334SMI 29

Chapter 3 - Class 1 Fax CommandsMT3334SMI 35Command: +FRS=? <Enter>Function: Display the range of stop-transmission-and-wait period valuesValue

Página 30 - Result Codes

ModemModule Developer’s GuideMT3334SMI36Command: +FRM=? <Enter>Function: Display the valid range of receive data modulation valuesValues: <

Página 31

Chapter 3 - Class 1 Fax CommandsMT3334SMI 37Flow ControlXON/XOFF flow control is used by the ModemModule to match the PC-to-modem data rate to theline

Página 32

ModemModule Developer’s GuideMT3334SMI38Table 3-2. Single-Page Class 1 Transmit ExampleAction by Action byCommand Respone Local Modem Remote PCAT+FCL

Página 33

Chapter 3 - Class 1 Fax CommandsMT3334SMI 39Table 3-3. Single-Page Class 1 Answer & Receive ExampleAction by Action byCommand Respone Local Modem

Página 34

ivAppendixesAppendix A - Regulatory Agency Compliance ...

Página 35

ModemModule Developer’s GuideMT3334SMI40

Página 36

Chapter 4 - Class 2 Fax Commands

Página 37 - Sample Sessions

ModemModule Developer’s GuideMT3334SMI42IntroductionThis chapter provides fax software developers with specific Class 2 fax command protocolinformatio

Página 38 - Action by Action by

Chapter 4 - Class 2 Fax CommandsMT3334SMI 4350 - 69 Transmit phase D hang-up codes52: No response to MPS repeated 3 times53: Invalid response to MPS

Página 39 - MT3334SMI 39

ModemModule Developer’s GuideMT3334SMI44+FDCC Fax Capability ParametersCommand syntax: +FDCC=VR,RB,WD,LN,DF,EC,BF,STResponse syntax: VR,BR,WD,LN,DF,EC

Página 40 - MT3334SMI40

Chapter 4 - Class 2 Fax CommandsMT3334SMI 454: 12000 bits/s V.33 or V.175: 14400 bits/s V.33 or V.17WD: Page width0: 1728 pixels in 215 mmLN: Page len

Página 41

ModemModule Developer’s GuideMT3334SMI46DF: Data compression format.0: 1-D modified HuffmanEC: Error correction.0: Disable ECMBF: Binary file transfer

Página 42

Chapter 4 - Class 2 Fax CommandsMT3334SMI 47+FK Session TerminationCommand syntax: +FKThis command causes the modem to terminate the session in an ord

Página 43 - +FCTCRTY ECM Retry Count

ModemModule Developer’s GuideMT3334SMI48+FPTS Page Transfer StatusCommand syntax: +FPTS=<ppr>1: MCF Page good2: RTN Page good; retrain requested

Página 44 - +FDCS Current Session Results

Chapter 4 - Class 2 Fax CommandsMT3334SMI 49+FDIS Reports DIS Frame InformationSyntax: +FDIS:VR,BR,WD,LN,DF,EC,BF,STUsage: Reports remote FAX capabili

Página 45

Chapter 1 - Introduction and Description

Página 46

ModemModule Developer’s GuideMT3334SMI50

Página 47

Chapter 5 - Remote Configuration

Página 48

ModemModule User GuideMT3334SMI52IntroductionRemote configuration is a network management tool that allows you to configure modems anywherein your net

Página 49 - +FTSI Report the Remote ID

Chapter 5 - Remote ConfigurationMT3334SMI 53Changing the Remote Escape CharacterTo increase security, you can change a remote modem’s remote configura

Página 50 - MT3334SMI50

ModemModule User GuideMT3334SMI54

Página 51

Chapter 6 - Troubleshooting

Página 52 - Basic Procedure

ModemModule Developer’s GuideMT3334SMI56IntroductionEach time you turn on your modem, it performs an automatic self-test to ensure proper operation.Yo

Página 53

Chapter 6 - TroubleshootingMT3334SMI 576. Your modem passes this test if the data received on your monitor are the same as the dataentered from your k

Página 54 - MT3334SMI54

ModemModule Developer’s GuideMT3334SMI58Local Digital Loopback Test (V.54 Loop 2)The local digital loopback test is identical to the remote digital lo

Página 55 - Chapter 6 - Troubleshooting

Chapter 7 - Upgrade Procedure

Página 56

ModemModule Developer’s GuideMT3334SMI6IntroductionThe MT3334SMI socket modem provides a fully-integrated data and fax communications design forcommun

Página 57 - Test procedure

ModemModule Developer’s GuideMT3334SMI60IntroductionYour ModemModule is controlled by semi-permanent firmware that is stored in flash memory.Firmware

Página 58 - Test Procedure

Chapter 7 - Upgrade ProcedureMT3334SMI 61Multi-Tech BBS1. Run your favorite terminal program and dial in to the Multi-Tech BBS at 800-392-2432 (NorthA

Página 59 - Chapter 7 - Upgrade Procedure

ModemModule Developer’s GuideMT3334SMI62Step 4: Extract the Upgrade Files1. Move the downloaded upgrade file to a temporary directory or folder on you

Página 61 - Multi-Tech Web Site

ModemModule Developer’s GuideMT3334SMI64Appendix A - Regulatory Agency ComplianceFCC Regulations for Telephone Line Interconnection1. This equipment

Página 62

AppendixesMT3334SMI 65Canadian Limitations Notice:NOTICE: The Industry Canada label identifies certified equipment. This certification means that the

Página 63

ModemModule Developer’s GuideMT3334SMI66EMC, Safety and Terminal Directive ComplianceThe CE mark is affixed to this product to confirm compliance with

Página 64

AppendixesMT3334SMI 67Appendix B - Multi-Tech Flash Programming ProtocolIntroductionThis appendix describes the protocol by which the modems are flas

Página 65 - FCC FAX Update

ModemModule Developer’s GuideMT3334SMI68Program SequenceDTE Modem CommentsATFLP\r Request to the modem to program G Modem is ready for next program p

Página 66

AppendixesMT3334SMI 693.3. The packets sent to the modem must be presorted by address and aligned on 128 byteboundaries (ie. each packet must start on

Página 67 - 1. Programming the Modem

Chapter 1 - Introduction and DescriptionMT3334SMI 7Technical SpecificationsThe ModemModule meets the following specifications:Data Rates Client-to-S

Página 68 - 3. Other programming concerns

ModemModule Developer’s GuideMT3334SMI70Extended Address RecordChar Pos Field Type Value Description1 Record Start “:”2-3 Data Byte Count “02 Always 2

Página 69 - Data Record

MT3334SM71IndexIndexAAbort timer... 28Analog loopback test ...

Página 70 - End of File Record

MT3334SM72ModemModule Developer’s GuideClass 1 fax commandsSample sessions ... 37Class 2 Fax commandsImple

Página 71

MT3334SM73IndexMT3334SMIDesign Considerations... 14Features ...

Página 72

MT3334SM74ModemModule Developer’s GuideUUpgrading the modem ... 60VV.22 mode ...

Página 73

ModemModule Developer’s GuideMT3334SMI8Carrier Frequencies Transmit originate: 390 Hz mark ITU-T V.23 450 Hz space (1200 bps) Receive origin

Página 74

Chapter 1 - Introduction and DescriptionMT3334SMI 9Physical DimensionsFigure 1-2 illustrates the the physical dimensions of the MT3334SMI..020 ± .0002

Comentários a estes Manuais

Sem comentários