Resumo do Conteúdo

Página 1 - User Guide

MT2834BR/MT2834BLRIntelligent Data/FaxRack Mounted ModemUser Guide

Página 2 - Revision Date Description

10Chapter 2 - Installation2.2 InstallationPerform the following procedure to install modem cards in the CC916,CC1416, CC2816 or CC1600 racks*. The ins

Página 3 - Contents

11Chapter 2 - Installation9. Set both local and remote modems to either Normal (&E0&W0) modeor to Reliable (&E2&W0) mode.10. Verify le

Página 4

12Chapter 2 - InstallationThe sixteen DIP-Switches and two berg jumpers control various modemoptions or set default values for the MT2834 Command mode

Página 5 - Chapter 1 - Introduction

13Chapter 2 - InstallationSwitch Function Position Effect#5 Answer/Originate* UP* Originate call in(Async/Sync/Leased Line) DOWN Lease Line mode#6 Max

Página 6 - 1.2 Features

14Chapter 2 - InstallationDip Switch Settings #13 - 16Note: A modem baud rate command (e.g., $MB33600) overrides thesetting of the speed selection swi

Página 7 - 1.3 How to Use This Manual

15Chapter 2 - Installation2.4.1 Out of Service/Test JumperWhen the MT2834 is Out Of Service (OOS), it is busy to incoming calls. Inthe Test (default)

Página 8

16Chapter 2 - Installation2.5 Dial-Up and Leased LinesConnection to the phone system is made via RJ11 type jacks such as anRJ11C or RJ11W. It can als

Página 9 - 2.1.3 Telephone Line

17Chapter 2 - Installation2.6 Modem LED IndicatorsThe MT2834 has ten LED diagnostic indicators.1. Receive Data (RCV). This LED blinks when data is bei

Página 10 - 2.2 Installation

18Chapter 2 - Installation10. Error (ERR). When the ERR LED is flashing, the leased line is downand the modem is in self-test mode has failed. When ER

Página 11 - 2.3 PC Board Controls

Chapter 3 - Installation

Página 12 - 2.3.1 DIP-Switch Settings

MT2834BR/MT2834BLR User GuidePN: S000316Copyright ©2003 by Multi-Tech Systems, Inc.All rights reserved. This publication may not be reproduced, in who

Página 13

20Chapter 3 - Configuration3.1 IntroductionSince your communications software configuration is affected by thecapabilities of your computer, this chap

Página 14

21Chapter 3 - Configurationcompromised by other serial communications, including printertransmissions and Appletalk, the networking software that allo

Página 15 - 2.4.2 MI/MIC Option Jumper

22Chapter 3 - ConfigurationFigure 3-1. MSD UART Identification, Screen 1Figure 3-2. MSD UART Identification, Screen 2

Página 16 - 2.5 Dial-Up and Leased Lines

23Chapter 3 - Configuration3.3 Configuring Your SoftwareCommunications software must be configured to work with your modem,your computer, and the remo

Página 17 - 2.6 Modem LED Indicators

24Chapter 3 - Configuration3.4 PC Initialization StringsWe recommend the following initialization string for a MT2834 connectedto a PC-compatible comp

Página 18

25Chapter 3 - ConfigurationFigure 3-2. The MEW Modem Initialization Setup* Note that the above and following set up screens are examples found inMulti

Página 19 - Chapter 3 - Installation

26Chapter 3 - Configuration3.4.1 Changing Default ParametersThe default values for the other parameters in modem configuration menusrarely need changi

Página 20 - 3.2 Serial Port Limitations

27Chapter 3 - Configuration3.6 Configuring Software for Your ComputerConfigure the communications software to match the computer’sconfiguration. If th

Página 21

28Chapter 3 - Configuration3.6.1 Configuring Software for the Remote SystemYou must meet the requirements of the remote system for successfulcommunica

Página 22

29Chapter 3 - Configuration3.6.3 File Transfer ProtocolsWhen you upload or download files with your modem, the host computerwill ask which file transf

Página 23 - 3.3 Configuring Your Software

ContentsChapter 1 - Introduction ... 51.1 Introduction ...

Página 24 - 3.4 PC Initialization Strings

30Chapter 3 - ConfigurationThe command to disable compression is AT &E14 <CR>. If you have anolder UART or if you use your modem mostly for

Página 25

Chapter 4 - ModemCommands

Página 26 - 3.5 Macintosh Initialization

32Chapter 4 - Commands4.1 Modem AT CommandsAT commands are the means by which you, and your communicationssoftware, are able to communicate with and c

Página 27

33Chapter 4 - CommandsCOMMAND: $AnVALUES: n = 0 or 1DEFAULT: $A0DESCRIPTION: $A0 discards data during auto-reliable time period. $A1buffers data durin

Página 28 - 3.6.2 Terminal Emulation

34Chapter 4 - CommandsVALUES: n = 0, 1, 2 or 4DEFAULT: &C1DESCRIPTION: &C0 forces Carrier Detect on.&C1 lets Carrier Detect act normally.&

Página 29 - 3.6.3 File Transfer Protocols

35Chapter 4 - CommandsVALUES: n = 0 or 1DEFAULT: %DP0DESCRIPTION: %DP0 selects do not read Line Probe Information fromDSP during handshaking.%DP1 sele

Página 30

36Chapter 4 - CommandsVALUES: n = 0 thru 2DEFAULT: #F2DESCRIPTION: #F0 means no fallback when on-line.#F1 means fallback from 33600 to 4800 bps when o

Página 31 - Commands

37Chapter 4 - CommandsVALUES: n = 1 thru 3DEFAULT: Read Only CommandDESCRIPTION: $H1 brings up Help Screen #1.$H2 brings up Help Screen #2.$H3 brings

Página 32 - 4.1 Modem AT Commands

38Chapter 4 - CommandsVALUES: n = speedDEFAULT: $MB33600 bpsDESCRIPTION: $MB75 selects CCITT V.23 mode.$MB300 selects 300 bps on-line.$MB1200 selects

Página 33

39Chapter 4 - CommandsVALUES: n = 0, 1 or 2DEFAULT: Q0DESCRIPTION: Q0 selects Result Codes displayed.Q1 selects Result Codes suppressed (quiet).Q2 sel

Página 34

4.2 S-Registers... 484.3 Result Codes...

Página 35

40Chapter 4 - CommandsVALUES: r = 0-11, 13, 15-17, 24-26, 29, 30, 32, 34, 36, 37, 48DEFAULT: n/aDESCRIPTION: Reads value of S-Register “r” and display

Página 36

41Chapter 4 - CommandsVALUES: n = 4 or 5DEFAULT: &T5DESCRIPTION: &T4 selects Enable Response to Request for RemoteDigital Loopback.&T5 sel

Página 37

42Chapter 4 - CommandsDEFAULT: X0DESCRIPTION: X0 selects Basic Result Codes (w/o CONNECT 1200,CONNECT 2400).X1 selects Extended Result Codes (w/CONNEC

Página 38

43Chapter 4 - CommandsDEFAULT: n/aDESCRIPTION: Causes modem to wait for ringback, then 5 seconds ofsilence before processing next part of command.COMM

Página 39

44Chapter 4 - CommandsDEFAULT: n/aDESCRIPTION: Callback password with xxxxxx being callback passwordand yy being the memory location. Callback passwo

Página 40

45Chapter 4 - Commands4.1.2 Remote ConfigurationThe Remote Configuration feature is a network management tool thatallows you to configure modems remot

Página 41

46Chapter 4 - CommandsYou can now use any AT commands of the modem being remotelyconfigured as if they were being entered locally. You cannot change t

Página 42

47Chapter 4 - CommandsCOMMAND: CSPsVALUES: n/aDEFAULT: n/aDESCRIPTION: The CSP command will change the serial baud rate of yourmodem by entering CSPss

Página 43

48Chapter 4 - Commands4.2 S-RegistersCertain Command Mode configurations are stored in memory registerscalled, S-Registers. The S command is used to

Página 44

49Chapter 4 - CommandsS4Line Feed CharacterUnit: ASCII CharacterRange: 0-127Default: 10Description: Defines the character recognized as LINE FEED.S5Ba

Página 46 - 4.1.4 V.25bis Commands

50Chapter 4 - CommandsS10Carrier Loss Disconnect Delay TimeUnit: 100 mSec.Range: 0-255Default: 7Description: Sets the time a carrier signal must be lo

Página 47

51Chapter 4 - CommandsS25DTR Dropout TimeUnit: 100 mSec.Range: 0, 1 through 255Default: 0Description: Defines DTR dropout time. 0 default equals 50ms.

Página 48 - 4.2 S-Registers

52Chapter 4 - CommandsS36Time Between DTR Inactive and Modem Off-HookUnit: 1 SecondRange: 0-255 secondsDefault: 0Description: Sets the time between DT

Página 49

53Chapter 4 - CommandsTERSE VERBOSE0OK1 CONNECT2 RING3 NO CARRIER4 ERROR5 * CONNECT 12006 NO DIALTONE7 BUSY8 NO ANSWER9 * CONNECT 240011 * CONNECT 480

Página 50

54Chapter 4 - CommandsTERSE VERBOSE0OK1 CONNECT2 RING3 NO CARRIER4 ERROR5 CONNECT 12006 NO DIAL TONE7 BUSY8 NO ANSWER10 CONNECT 240011 CONNECT 480012

Página 51

55Chapter 4 - Commands4.3.1 AT Commands and S-Register SummaryThe vast majority of installations are similar, with the MT2834 being usedto dial up a r

Página 52 - 4.3 Result Codes

Chapter 5 - Modem Testing

Página 53

57Chapter 5 - Testing the Modem5.1 Local Analog Loopback Test/V.54 Loop 3In this test, data from your computer or terminal is sent to your modem'

Página 54

58Chapter 5 - Testing the ModemATU1 and hit ENTER to place the modem in Analog Loopback mode, inthe Answer mode. Then repeat step 3.5. When testing is

Página 55

59Chapter 5 - Testing the Modem2. Dial the remote modem by entering the Dial command and the phonenumber, to establish On-line mode.3. Type the Escape

Página 56 - Chapter 5 - Modem Testing

6Chapter 1 - Introduction1.1 IntroductionWelcome to the world of data communications. You have acquired one ofthe finest intelligent data/fax modems

Página 57 - Chapter 5 - Testing the Modem

60Chapter 5 - Testing the Modem5.3 Digital Loopback Test/V.54 Loop 2(Remote/Automatic)In this test, your modem must be On-line with another modem set

Página 58

61Chapter 5 - Testing the Modem5.4 Local Analog Loopback Test (Synchronous Mode)To initiate the Local Analog Loopback Test, with the modem inSynchrono

Página 59

62Chapter 5 - Testing the Modem5.5 Digital Loopback Test (Local/Manual)(Synchronous Mode)This test must be run when you have a data connection with an

Página 60 - (Remote/Automatic)

63Chapter 5 - Testing the Modem5.6 Digital Loopback Test (Remote/Automatic) (Synchronous Mode)This test must be run when you have a dat

Página 61

Chapter 6 - Warrantyand Service

Página 62 - (Synchronous Mode)

65Chapter 6 - Warranty and Service6.1 IntroductionThis chapter starts out with statements about your modem's 2-yearwarranty. The next section, Te

Página 63 - (Synchronous Mode)

66Chapter 6 - Warranty and Service6.3 Tech SupportMulti-Tech has an excellent staff of technical support personnel availableto help you get the most o

Página 64 - Chapter 6 - Warranty

67Chapter 6 - Warranty and Service• check or purchase order number for payment if the modem is out ofwarranty. (Check with your technical support spec

Página 65 - 6.2 Limited Warranty

68Chapter 6 - Warranty and Serviceand select the rate you want to program at. Hit ESC whenfinished.5. Highlight the "Select File to Program&quo

Página 66 - 6.3.2 Service

69Chapter 6 - Warranty and Service6.6 InternetMulti-Tech is a commercial provider on the Internet, and we retrievee-mail messages from the following m

Página 67 - 6.4 Upgrading the MT2834BR

· Automatic disabling of compression when transferring already-compressed files.· Serial port data rates adjustable to 115.2K bps.· Autodial, redial,

Página 68 - 6.5 Safety Warnings

Chapter 7 - BABTRequirements

Página 69 - 6.6 Internet

71Chapter 7 - BABT Requirements7.1 Compliance with BABT RequirementsApproved for connection to telecommunications system specified in theinstructions

Página 70 - Requirements

72Chapter 7 - BABT Requirements7.1.1 European Low Voltage DirectiveWhen correctly installed and maintained, the modem will present nohazard to the use

Página 71 - Chapter 7 - BABT Requirements

If a telephone or other device is connected in parallel with the modem, thecombined REN must not exceed 4. A BT supplied telephone may beassumed to ha

Página 72

74Chapter 7 - BABT Requirements7.1.4 Compliance with BS6328 Part 1a. The modem is not suitable for use on circuits with BritishTelecommunications sign

Página 73

Appendices

Página 74

76Appendix AAppendix A FCC Regulations for Telephone Line Interconnection1. This equipment complies with Part 68 of the Federal CommunicationsCommissi

Página 75 - Appendices

77Appendix A5. The telephone company may make changes in its facilities, equipment,operations, or procedures that could affect the operation of theequ

Página 76 - Appendix A

78Appendix ACanadian Limitations NoticeNotice: The ringer equivalence number (REN) assigned to each terminaldevice provides an indication of the maxim

Página 77

79Appendix BAppendix BTechnical SpecificationsYour MT2834BR/BRL data/fax modem meets the specifications listedbelow:Model Numbers MT2834BR, MT2834BRI,

Página 79 - Technical Specifications

80Appendix BFlow Control Xon/Xoff, Hardware RTS/CTS, ENQ/ACK,Options Unix-to-Unix Copy Protocol (UUCP) "Spoofing"Mode of Operation Full dupl

Página 80

81Appendix BFrequencies 1650Hz Mark, 1850Hz Space for TransmitOriginate; 1650Hz Mark, 1850Hz Space forTransmit Answer; V.27ter 1800Hz Originate/Answer

Página 81

82Appendix BFrequency Stability ±0.01%Receiver Sensitivity -43 dBm under worst case conditionsAGC Dynamic Range 43 dBInterface EIA RS232C/ITU-TSS V.24

Página 83

84IndexIndexSymbols&E0 1-32&E1 1-32&E14 1-31, 1-321.1 Technical Specifica-tions 1-81AAbort TimerS7 1-51AGC Dynamic Range 1-84ASCII code 1-

Página 84

85IndexClear to Send 1-41cleardown on disconnect 1-36COM portsCOM2 1-29Command Buffer 1-82Command mode characters control 1-37Command string 1-26Comma

Página 85

86IndexData Terminal Ready 1-19Datacomm software 1-22, 1-25, 1-26, 1-29, 1-30, 1-31Configuration 1-25, 1-29, 1-30Diagnostics 1-84Dial-Up and Leased Li

Página 86

87IndexInactivity Timer 1-53S30 1-53Indicators 1-84Initialization strings 1-25, 1-28, 1-32Macintosh 1-28PC-compatible 1-26Installation 1-12Intelligent

Página 87

88IndexChanging defaults 1-28Parity 1-25pause during dialing 1-44Pause Time for Comma 1-51S8 1-51PBX/CBX Disconnect DropTime for DSR/CTS/CD 1-52S24 1-

Página 88

89Index39Signal to Noise Ratio Informa-tion 1-39SIT files 1-31Speed Conversion 1-81speed conversion 1-35Standard AT command setresponses 1-54"St

Página 89

9Chapter 2 - Installation2.1 Preliminaries This chapter covers MT2834 installation and connection. In addition to thecontents of the MT2834 package

Página 90