Página 1 - Owner’s Manual

Model Number MT5634ZPW-PCIOwner’s Manual

Página 2

MT5634ZPW-PCI10Owner’s Manual• Automatic disabling of compression when transferringalready-compressed files.• Redial, pulse (rotary) and touch-tone di

Página 3 - Contents

MT5634ZPW-PCI111 Introduction and DescriptionPeripheral Component Interconnect (PCI)First developed by companies such as IntelTM, AT&TTM andDigi

Página 4 - Chapter 4 - Troubleshooting

MT5634ZPW-PCI12Owner’s ManualHow to Use This ManualChapter 1: Introduction and DescriptionThis chapter introduces the MT5634ZPW-PCI, briefly describin

Página 5

MT5634ZPW-PCI131 Introduction and DescriptionChapter 6: Warranty, Service, and Technical SupportThis chapter contains the terms of your warranty and

Página 6

MT5634ZPW-PCI14Owner’s ManualTypographic ConventionsThis manual uses the following typographic conventions:You type this Text entered by you is shown

Página 7

Chapter 2 - Installation

Página 8 - Congratulations

MT5634ZPW-PCI16Owner’s ManualIntroductionThis chapter describes how to install the MultiModemZPW-PCIinto your computer and the MultiModemZPW-PCI drive

Página 9 - General features include:

MT5634ZPW-PCI172 InstallationSafety Warnings• Never install telephone wiring during a lightning storm.• Never install telephone jacks in wet location

Página 10 - MT5634ZPW-PCI

MT5634ZPW-PCI18Owner’s ManualSound Card ConsiderationsIf you want speakerphone functions along with the ability torecord sound or .WAV files through t

Página 11

MT5634ZPW-PCI192 InstallationInstall the MultiModemZPW-PCI into theComputerInstallation of the MultiModemZPW-PCI requires you to openyour computer. P

Página 12 - How to Use This Manual

Owner’s Manual82078500 Revision A#MT5634ZPW - PCIThis publication may not be reproduced, in whole or in part, without priorexpressed written permissio

Página 13 - Appendices

MT5634ZPW-PCI20Owner’s ManualExternal ConnectionsThe MultiModemZPW-PCI communicates over public switchedtelephone network lines. Use the modular telep

Página 14 - Typographic Conventions

MT5634ZPW-PCI212 InstallationInstalling Drivers1. Plug in and turn on your computer. As your computer boots,it automatically detects the MultiModemZP

Página 15 - Chapter 2 - Installation

MT5634ZPW-PCI22Owner’s ManualVerifying ConfigurationUse the following procedure to check the assignments Windowshas made for your modem:1. Click on th

Página 16 - What You’ll Need

MT5634ZPW-PCI232 Installation10. Write down the modem’s port, interrupt, address, andhighest speed. You will need this information to set up any“lega

Página 17 - Installation

MT5634ZPW-PCI24Owner’s ManualOperating Your MultiModemZPW-PCIYou control your MultiModemZPW-PCI by issuing ATcommands and setting S-Registers. Right n

Página 18 - Sound Card Considerations

MT5634ZPW-PCI252 InstallationSimple OperationsYou can dial by using the ATD command and the phone numberof the modem with which you wish to connect,

Página 19 - Computer

MT5634ZPW-PCI26Owner’s ManualTesting the MultiModemZPW-PCI’s DataFunctionsTest the modem’s data functions by using HyperTerminal to callthe Multi-Tech

Página 20 - External Connections

MT5634ZPW-PCI272 Installation10. From the Main Menu, type F to access the Files Menu, thentype D.11. Enter the name of the file you wish to download

Página 21 - Installing Drivers

MT5634ZPW-PCI28Owner’s ManualTesting the MultiModemZPW-PCI’s FAXFunctionsTest your modem’s fax capabilities by sending a fax to a faxmachine in your o

Página 22 - Verifying Configuration

MT5634ZPW-PCI292 Installation11. Click Next, then click Finish.12. Microsoft Fax opens the ZPW-PCI Test.doc file in WordPadand prints it to the Rende

Página 23

iiiContentsChapter 1 - Introduction and DescriptionCongratulations ... 8P

Página 24

MT5634ZPW-PCI30Owner’s ManualLoopback Testing1. Connect a microphone and speaker to the MultiModemZPW-PCI. To avoid feedback, make sure the microphone

Página 25 - Software Configuration

MT5634ZPW-PCI312 Installation6. Speak into the microphone to talk to the person on the otherend of the line, and listen over the speaker.7. Type ATH

Página 26 - Functions

MT5634ZPW-PCI32Owner’s Manual

Página 27

Chapter 3 - AT Commands, S-Registersand Result Codes

Página 28

MT5634ZPW-PCI34Owner’s ManualIntroductionCommunications software must be customized, or configured, tomake it work with your computer’s serial port an

Página 29 - Function

MT5634ZPW-PCI353 AT Commands, S-Registers and Result Codes4. If your legacy software doesn’t have the correct modeminitialization string, you must ch

Página 30 - Loopback Testing

MT5634ZPW-PCI36Owner’s Manual9. If you must dial 9 to get an outside line, edit the dialing prefixto include a 9 and a comma, e.g., ATDT9, (the commai

Página 31

MT5634ZPW-PCI373 AT Commands, S-Registers and Result CodesAT CommandsThis section summarizes your modem’s AT commands. For detailedinformation on the

Página 32

MT5634ZPW-PCI38Owner’s ManualCommand: A/ Repeat Last CommandValues: n/aDescription: Repeat the last command string. Do not precede thiscommand with AT

Página 33

MT5634ZPW-PCI393 AT Commands, S-Registers and Result CodesS Dial a telephone number previously stored usingthe &Zn=x command (see &Zn=x comma

Página 34

ivChapter 3 - AT Commands, S-Registers and ResultCodesIntroduction ...

Página 35 - NO DIALTONE

MT5634ZPW-PCI40Owner’s ManualCommand: InInformation RequestValues:n = 0–4, 9, 11Default: NoneDescription: I0 Display default speed and controller firm

Página 36

MT5634ZPW-PCI413 AT Commands, S-Registers and Result CodesCommand: O Return Online to Data ModeValues: 0, 1, 3Default: NoneDescription: O0 Exit onlin

Página 37 - AT Commands

MT5634ZPW-PCI42Owner’s ManualCommand: XnResult Code SelectionValues:n = 0–7Default: 4Description: X0 Basic result codes (e.g., CONNECT); does not look

Página 38

MT5634ZPW-PCI433 AT Commands, S-Registers and Result CodesCommand: &CnData Carrier Detect (DCD) ControlValues:n = 0 or 1Default: 1Description: &a

Página 39

MT5634ZPW-PCI44Owner’s ManualCommand: &KnLocal Flow Control SelectionValues:n = 0, 3, or 4Defaults: 3Description: &K0 Flow control disabled.&a

Página 40

MT5634ZPW-PCI453 AT Commands, S-Registers and Result CodesCommand: &WnStore Current ConfigurationValues:n = 0Default: NoneDescription: &W0 St

Página 41

MT5634ZPW-PCI46Owner’s ManualCommand: \NnError Correction Mode SelectionValues:n = 0–5, or 7Default: 3Description: \N0 Non-error correction mode with

Página 42

MT5634ZPW-PCI473 AT Commands, S-Registers and Result CodesCommand: -CnData Calling ToneValues:n = 0 or 1Defaults: 0Description: -C0 Disable V.25 data

Página 43

MT5634ZPW-PCI48Owner’s ManualCommand: %T125 Testing DSP 56K Code Version/ChecksumValues: n/aDescription: Entering AT%T125<cr> tests the DSP56K

Página 44

MT5634ZPW-PCI493 AT Commands, S-Registers and Result CodesRegister Unit Range Default DescriptionS6seconds 2–65* 2* Sets the time the modem will wait

Página 45

vAppendicesAppendix A: Regulatory Compliance ... 76Appendix B: Technical Specifications ...

Página 46

MT5634ZPW-PCI50Owner’s ManualRegister Unit Range Default DescriptionS37decimal 0–19 0 S37 sets the maximum V.34 "up-stream" speed that the m

Página 47

MT5634ZPW-PCI513 AT Commands, S-Registers and Result CodesRegister Unit Range Default DescriptionS42decimal 0–1 1 Enables/disables the 56K autorate.

Página 48 - S-Registers

MT5634ZPW-PCI52Owner’s ManualResult CodesIn command mode the MultiModemZPW-PCI sends result codesto your computer to provide you with on-going informa

Página 49

MT5634ZPW-PCI533 AT Commands, S-Registers and Result CodesTerse Verbose Description77* CONNECT 46000Connected at 46000 bps78* CONNECT 48000Connected

Página 50

MT5634ZPW-PCI54Owner’s Manual

Página 51

Chapter 4 - Troubleshooting

Página 52 - Result Codes

MT5634ZPW-PCI56Owner’s ManualIntroductionThis chapter covers some common problems you may run intowith your modem and how to solve them. YourMultiMode

Página 53

MT5634ZPW-PCI574 Troubleshooting• Retry whatever action was not working.• If it still does not work, check the following section for adescription and

Página 54

MT5634ZPW-PCI58Owner’s ManualThe Modem Does Not Respond toCommands• Make sure you are in terminal mode in your datacommunications program, then type A

Página 55

MT5634ZPW-PCI594 TroubleshootingCommunications Port your modem is connected to. In theport’s Properties sheet, click on the Resources tab to seethe p

Página 57 - Common Problems

MT5634ZPW-PCI60Owner’s ManualThe Modem Dials But Cannot Make aConnectionThere can be several reasons the MultiModemZPW-PCI fails tomake a connection.

Página 58 - Commands

MT5634ZPW-PCI614 Troubleshooting• If the modem reports BUSY, the other number may be busy,in which case you should try again later, or it may indicat

Página 59

MT5634ZPW-PCI62Owner’s ManualThe Modem Disconnects While Online• If you have call waiting on the same phone line as yourmodem, it may interrupt your c

Página 60 - Connection

MT5634ZPW-PCI634 TroubleshootingThe Modem Cannot Connect WhenAnswering• Auto-answer may be disabled. Turn on auto-answer in yourdata communications p

Página 61 - NO CARRIER

MT5634ZPW-PCI64Owner’s ManualThere Are Garbage Characters on theMonitor• Your computer and the remote computer may be set todifferent word lengths, st

Página 62

Chapter 5 - Warranty, Service andTechnical Support

Página 63 - Data Is Being Lost

MT5634ZPW-PCI66Owner’s ManualIntroductionThis chapter begins with the terms of your modem’s warranty.Read carefully the next section, “Tech Support,”

Página 64 - Same Time

MT5634ZPW-PCI675 Warranty, Service and Tech SupportMTS’s entire obligation under this warranty shall be limited (atMTS’s option) to repair or replace

Página 65 - Technical Support

MT5634ZPW-PCI68Owner’s ManualThe modem model and serial numbers are silkscreened on yourmodem. The software versions are printed on the diskette label

Página 66 - Limited Warranty

MT5634ZPW-PCI695 Warranty, Service and Tech SupportServiceIf your technical support specialist decides that service isrequired and you are outside th

Página 67 - Recording Modem Information

Chapter 1 - Introduction and Description

Página 68

MT5634ZPW-PCI70Owner’s ManualThe Multi-Tech BBSMulti-Tech maintains a bulletin board system (BBS) for itscustomers. Information available from the BBS

Página 69 - Attn: Repair

MT5634ZPW-PCI715 Warranty, Service and Tech SupportDownloading a FileIf you know the file name1. From the Main Menu, type F to access the Files Menu,

Página 70 - The Multi-Tech BBS

MT5634ZPW-PCI72Owner’s Manual6. Select a file transfer protocol by typing the indicated letter,such as Z for Zmodem (the recommended protocol).7. If y

Página 71 - Downloading a File

MT5634ZPW-PCI735 Warranty, Service and Tech SupportAbout CompuServeIn addition to the BBS, Multi-Tech provides support throughCompuServe’s Modem Vend

Página 72 - Bulletins

MT5634ZPW-PCI74Owner’s ManualAbout the Multi-Tech Fax-Back ServiceMulti-Tech's fax-back system provides 24-hour access to sales,marketing, and te

Página 74

MT5634ZPW-PCI76Owner’s ManualAppendix A: Regulatory ComplianceFCC Regulations for Telephone LineInterconnection1. This equipment complies with Part 68

Página 75

MT5634ZPW-PCI77Appendices5. The telephone company may make changes in its facilities,equipment, operations, or procedures that could affect theoperati

Página 76 - Interconnection

MT5634ZPW-PCI78Owner’s ManualNOTE: This equipment has been tested and found to comply with the limitsfor a Class B digital device, pursuant to Part 15

Página 77

MT5634ZPW-PCI79AppendicesCanadian Limitations NoticeNotice: The ringer equivalence number (REN) assigned to eachterminal device provides an indication

Página 78

MT5634ZPW-PCI8Owner’s ManualCongratulationsCongratulations on your purchase of one of the finest internaldata/fax/voice modems available today: the Mu

Página 79 - Canadian Limitations Notice

MT5634ZPW-PCI80Owner’s ManualThis digital apparatus does not exceed the Class B limits forradio noise emissions from digital apparatus set out in the

Página 80 - Ringer Equivalence Number

MT5634ZPW-PCI81AppendicesCompliance with BABT RequirementsApproved for connection to telecommunications systemspecified in the instructions for use su

Página 81

MT5634ZPW-PCI82Owner’s Manualbecome conductive due to condensation. Failure to maintainthese minimum distances would invalidate approval.Figure A-1. C

Página 82

MT5634ZPW-PCI83AppendicesExcept at the edge connector which plugs into the host'sexpansion slot, clearance distance (Xmm) and creepagedistance (Y

Página 83

MT5634ZPW-PCI84Owner’s ManualCompliance with BS6305 Clause 6.2,BS6320 Clause 7.2, and BABT/SITS/82/005S/Da. The modem is suitable for connection to th

Página 84

MT5634ZPW-PCI85Appendicesi. internal software that has not been formally accepted byBABT.ii. external control software or external control apparatus w

Página 85 - APPROVED for connection to

MT5634ZPW-PCI86Owner’s ManualCompliance with BS6789: Section 3.1 andPart 2a. The modem is not capable of allowing Auto Call using '999'or ot

Página 86 - Compliance with BS6328 Part 1

MT5634ZPW-PCI87AppendicesEuropean Community Directives (CE)The CE mark is affixed to the enclosed MultiTech product toconfirm compliance with the foll

Página 87

MT5634ZPW-PCI88Owner’s ManualAustralian and New Zealand Modem WarningNoticeAustralian Modem Warning NoticeModems connected to the Australian telecommu

Página 88 - Call Attempts/Retries:

MT5634ZPW-PCI89AppendicesFailure to set the modem, and any communications softwareused with the modem, to the values shown above will result inthe mod

Página 89 - PC Cards)

MT5634ZPW-PCI91 Introduction and DescriptionThe MultiModemZPW-PCI is a full-featured internal data/fax/voice modem designed for Pentium computers in

Página 90

MT5634ZPW-PCI90Owner’s ManualAppendix B: Technical SpecificationsTrade NameMultiModemZPW-PCIModel NumbersMT5634ZPW-PCIClient-to-ServerData Rates*K56fl

Página 91

MT5634ZPW-PCI91AppendicesError CorrectionITU V.42 (LAP-M and MNP Classes 2–4)Data CompressionITU V.42bis (4:1 compression) and MNP 5(2:1 compression)S

Página 92

MT5634ZPW-PCI92Owner’s ManualCommand Buffer40 charactersData ModulationsFSK at 300 bps, DPSK at 1200 bps, QAMat 2400, 4800, and 9600 bps (non-trellis)

Página 93

MT5634ZPW-PCI93AppendicesFax Carrier FrequenciesV.21 CH2 (half duplex):1650 Hz mark, 1850 Hz space forTransmit Originate;1650 Hz mark, 1850 Hz space f

Página 94

MT5634ZPW-PCI94Owner’s ManualAppendix C: ASCII Conversion ChartCTRL CODE HEX DEC CODE HEX DEC CODE HEX DEC CODE HEX DEC@ NUL 00 0 SP 20 32 @ 40 64 ` 6