S48
Unit: decimal
Range: 7 or 128
Default: 7
Description: The following chart lists the S36 and S48
configuration settings necessary to negotiate
certain types of connections.
Register:
S89
Unit: seconds
Range: 0, 5-255
Default: 10
Description: Sets the length of time in the off-line command
mode before the modem goes into standby mode.
A value of zero prevents standby mode; a value of
1–4 sets the value to 5.